2.2 Power Supply Specifications

2.2.1 AC Power Supply
Item
Rated voltage
Voltage regulation range
Inrush current
Momentary power off time
Frequency
Leakage current
Internal power supply part
Guaranteed life
Fuse
Insulation system
Terminal screw
2.2.2 Service Power supply for Input (Output) (L30, L40 and L60 only)
Item
Rated output voltage
Voltage regulation range
Rated output current
Overcurrent protection
Note)
function
Terminal screw
Note) This is a function to protect overcurrent temporarily, which protects the output short-circuit. If the
short-circuit is detected, all the power supply for the PLC will be turned off. If a current load that is
out of the specifications is connected and the overloaded status continues, it may lead to damages.
2-4
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
100 to 240 V AC
85 to 264 V AC
L14: 35A or less (at 240 V AC, 25 C)
L30/L40/L60: 40A or less (at 240 V AC, 25 C)
10 ms (when using 100 V AC)
50/60 Hz (47 to 63 Hz)
0.75 mA or less between input and protective earth terminals
20,000 hours (at 55 C)
Built-in (Cannot be replaced)
Transformer insulation
M3
24 V DC
21.6 to 26.4 V DC
Available
M3
Specifications
Specifications
0.4 A