12.1.2 Performance Specifications
Item
Control unit
No. of
contro-
llable
When using E16R
I/O
expansion I/O units
points
When using E30R
expansion I/O units
Programming method/Control
method
Program memory
Program capacity
Basic
No. of
instruction
High-level
Operation speed
Base time
I/O refresh + base time
External input (X)
External output (Y)
Internal relay (R)
Special internal relay (R)
Timer/Counter (T/C)
Link relay(L)
Data register (DT)
Special data register
(DT)
Link data register (LD)
Index register (I)
Differential points
Master control relay points
(MCR)
No. of labels (JP and LOOP)
No. of step laddars
No. of subroutines
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
L14
14 points
DC input: 8,
Ry output: 4
Tr output: 2
-
-
Relay symbol/Cyclic operation
Built-in Flash ROM (without backup battery)
2.5k steps
114
230
From 0.08 µs/step (by basic instruction)
From 0.32 µs/step (by high-level
instruction) (MV instruction)
0.15 ms
With E16: 0.4 ms x No. of units
With E30: 0.5 ms x No. of units
With expansion FP0 adapter: 1.4 ms + FP0 expansion unit refresh time
Note1)
960 points (X0 to X59F)
Note1)
960 points (X0 to X59F)
1008 points (R0 to R62F)
224 points
Note2)
256 points
(for initial setting, Timer: 250 points (T0
to T249), Counter: 6 points (C250 to
C255))
Timer: can count up to (in units of 1ms,
10ms, 100ms or 1s)× 32767.
Counter: Can count up to 1 to 32767.
None
2500 words (DT0 to DT2499)
420 words
None
14 words (I0 to ID)
Unlimited points
32 points
100 points
128 stages
100 subroutines
Descriptions
L30
30 points
40 points
DC input: 16,
DC input: 24,
Ry output: 10
Ry output: 12
Tr output: 4
Tr output: 4
Max. 88 points
-
(Max. 3 units)
Max. 130 points
-
(up to 3 units)
2.5k steps
8k steps
Up to 3k steps:
From 0.08 µs/step (by basic
instruction)
From 0.32 µs/step (by high-level
instruction) (MV instruction)
From 3k steps:
From 0.58 µs/step (by basic
instruction)
From 1.62 µs/step (by high-level
instruction) (MV instruction)
0.31 to 0.35 ms or
0.18 ms
less
1760 points (Y0 to Y109F)
1760 points (Y0 to Y109F)
4096 points (R0 to R255F)
224 points
1024 points
(for initial setting, Timer: 1008 points
(T0 to T1007), Counter: 16 points
(C1008 to C1023))
Timer: can count up to (in units of 1ms,
10ms, 100ms or 1s)× 32767.
Counter: Can count up to 1 to 32767.
2048 points (L0 to L127F)
8192 words (DT0 to DT8191)
420 words
256 word
14 words (I0 to ID)
256 points
256 points
1000 stages
500 subroutines
L40
L60
60 points
DC input: 32,
Ry output: 24
Tr output: 4
Max. 108 points
(Max. 3 units)
Max. 150 points
(up to 3 units)
8k steps
0.34 to 0.39 ms or
less
Note6)
Note2)