7.4.7 JOG Operation Instruction (F172)
This instruction is used to output pulses according to a specified parameter when the trigger (execution
-
condition) is on.
When the trigger (execution condition) turns off, deceleration is performed within a specified
-
deceleration time. However, if the trigger turns on again, acceleration is performed up to the target
speed again.
When the deceleration stop is requested by the F0 instruction during the pulse output, the deceleration
-
stop is performed.
There are two kinds of control method, which are type 0 and type 1.
-
Operation modes of JOG operation
There are two operation modes for the JOG operation, which are type 0 and type 1. Those operation
specifications for the specified target value differ.
Type 0
Regardless of the settings for the target value, the JOG operation is performed when the trigger is on.
Type 1
Even if the trigger is on, the deceleration stop is performed according to the settings of the target value.