Panasonic FP-X0 L14R User Manual page 232

Table of Contents

Advertisement

Address
Name
2.5 ms ring
DT90019
counter
10 µs ring counter
DT90020
Note2) Note3)
DT90021
Not used
Scan time (current
DT90022
Note1)
value)
Scan time
DT90023
(minimum value)
Note1)
Scan time
DT90024
(maximum value)
Note1)
Mask condition
monitoring
DT90025
register for
interrupts
(INT0 to 7)
DT90026
Not used
Periodical
DT90027
interrupt interval
(INT24)
Sample trace
DT90028
interval
DT90029
Not used
Note1) Scan time display is only possible in RUN mode, and shows the operation cycle time. (In PROG.
mode, the scan time for the operation is not displayed.) The maximum and minimum values are
cleared each time the mode is switched from RUN to PROG.
Note2) It is renewed once at the beginning of each one scan.
Note3) As DT90020 is renewed even if F0(MV), DT90020 and D instruction is being executed, it can be
used to measure the block time.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
The data stored here is increased by one every
2.5 ms. (H0 to HFFFF)
Difference between the values of the two points
Note2)
(absolute value) x 2.5 ms = Elapsed time between
the two points.
The data stored here is increased by one every
10.67 µs. (H0 to HFFFF)
Difference between the values of the two points
(absolute value) x 10.67 µs = Elapsed time
between the two points.
Note) The exact value is 10.67 µs.
-
The current scan time is stored here. Scan time is
calculated using the formula:
Scan time (ms) = stored data (decimal) x 0.1 ms
Example: K50 indicates 5 ms.
The minimum scan time is stored here. Scan time
is calculated using the formula:
Scan time (ms) = stored data (decimal) x 0.1 ms
Example: K50 indicates 5 ms.
The maximum scan time is stored here. The scan
time is calculated using the formula:
Scan time (ms) = stored data (decimal) x 0.1 ms
Example: K125 indicates 12.5 ms.
The mask conditions of interrupts using the
instruction can be stored here. Monitor using
binary display.
-
The value set by ICTL instruction is stored.
K0: periodical interrupt is not used.
K1 to K3000: 0.5ms to 1.5s or 10ms to 30s
K0: Sampling by the SMPL instruction
K1 to K3000 (x 10 ms): 10 ms to 30 s
-
(A: Available, N/A: Not available)
Description
Read-
Writ
ing
-ing
A
N/A
A
N/A
N/A
N/A
A
N/A
A
N/A
A
N/A
A
N/A
N/A
N/A
A
N/A
A
N/A
N/A
N/A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fp-x0 l40mrFp-x0 l60rFp-x0 l30rFp-x0 l60mr

Table of Contents