7.4.10 Data Table Control Instruction (F174)
Pulses are output from the specified channel according to the specified data table.
-
Positioning is performed sequentially according to the values of data tables, and stops at the data table
-
that the value of pulse output stop (K0) is written.
When the deceleration stop is requested by the F0 instruction during the pulse output, the deceleration
-
stop is performed.
Example of timing chart
Data table
Data
Setting item (Unit)
register No.
DT100
Control code
DT102
Frequency 1 (Hz)
DT104
Target value 1 (pulses)
DT106
Frequency 2 (Hz)
DT108
Target value 2 (pulses)
DT110
Frequency 3 (Hz)
DT112
Target value 3 (pulses)
DT114
Frequency 4 (Hz)
DT116
Target value 4 (pulses)
DT118
End of table
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com
Example of
sample program
H1000 0010
Set according to the control code on the
Absolute
next page.
CW/CCW
K1000
K1000
Set frequencies in the following range.
K2500
K1 to K20000 (L14/L30 type)
K4000
K1 to K50000 (L40/L60 type)
K5000
Set target values in the following range.
K9000
K-2,147,483,648 to K+2,147,483,647
K1000
K11000
K0
K0 fixed
Settable range