Module 9206 Change setting of the PLC soft keys

With Module 9206, the settings of individual PLC soft keys in the PLC soft-key
structure can be changed:
n
PLC soft keys can be locked and unlocked. Locked PLC soft keys cannot be
used and are displayed accordingly.
n
PLC soft keys can be coupled to new operands.
• ACTION: These PLC soft keys are no longer confirmed via W304
(unless changed by Module 9205) to the PLC.
• PULSE, CHECK, RADIO: These PLC soft keys must be assigned an
operand by Module 9206, since they are not acknowledged via W304 to
the PLC (unless changed by Module 9205).
n
Couple PLC soft-keys to operands that
• Unlock the PLC soft keys in a set state
• Lock the PLC soft keys in a reset state
If a locked PLC soft key is pressed, it sets the marker M4577.
Call:
PS
D
<Resource handle>
Resource handle from Module 9203
PS
B/W/D/K <Soft-key number>
PS
B/W/D/K <Function>
0: Lock soft key
1: Unlock soft key
2: Decouple soft key from assigned operand
3: Couple new operand to soft key
4: Decouple the soft-key unlocking/locking from the
assigned operand
5: Couple the soft-key unlocking/locking with the operand
PS
B/W/D/K <Operand address>
Only for function 3 and 5, otherwise transfer 0
PS
B/W/D/K <Operand type>
Only for function 3 and 5, otherwise transfer 0
0: Marker M
1: Input I
2: Output O
3: Counter C
4: Timer T
CM
9206
HEIDENHAIN Technical Manual iTNC 530