Shutting down the
control
Resetting the
Control
7 – 4
The control must be shut down before it can be switched off. This is done
either with the soft key in Manual mode or by the PLC with Module 9189. If the
control is shut down (either with Module 9189 or with the soft key), M4179 is
set, the ready signal of the drives is removed, and the hard disk is set to sleep
mode.
M4179
Control is shut down
Module 9189 Shutting down the control
The control is shut down with Module 9189. After shutdown, the PLC remains
operable. It can therefore react to a signal to switch off the machine after
conclusion of this module.
The information windows, which appear during shutdown via soft key, do not
appear.
Call:
CM
9189
Error detection:
Marker
Value
Meaning
M4203
0
Control was shut down
1
Error code in W1022
W1022
Module was not called in a spawn job or submit job
Module 9279 Control reset
Module 9279 carries out a control reset. This means the control is shut down
and then restarted (the PLC cannot be run) or only the control is shut down
(the PLC can still be run).
In either case, no message is shown on the monitor to say that the control is
being shut down.
Call:
PS
B/W/D/K <Mode>
0: Shut down the control
1: Control is shut down and restarted
CM
9279
Error detection:
Marker
Value
Meaning
M4203
0
Control reset is carried out
1
Error code in W1022
W1022
2
Invalid mode
20
Module was not called in a spawn job or submit job
Set
NC
HEIDENHAIN Technical Manual iTNC 530
Reset