Connection
overview for the
PL 410 B
X15 to X18: Analog
input on the
PL 410 B
X19 to X22:
Connection for Pt
100 on the PL 410 B
3 – 34
Pin layout
Connecting terminals
1
2
3
Note
The interfaces comply with the requirements of EN 50 178 for "low voltage
electrical separation."
Pin layout:
Connecting terminals
1
2
3
4
5
Note
The interfaces comply with the requirements of EN 50 178 for "low voltage
electrical separation."
Assignment
-10 V to +10 V
0 V (ref. potential)
Shield
Assignment
I + Constant current for Pt 100
U + Measuring input for Pt 100
U – Measuring input for Pt 100
I – Constant current for Pt 100
Shield
HEIDENHAIN Technical Manual iTNC 530