February 2002
Module 9175 Spindle switchover
With this module you can switch between spindle 1 and spindle 2. When
switching via an M strobe, MP7440 bit 2 must not be set. When switching via
an S or G strobe, MP3030 or MP13030, respectively, must not be set. The
module only needs to be called once.
Call:
PS
B/W/D/K <>Spindle number>
0: First spindle
1: Second spindle
CM
9175
Error detection:
Marker
Value
Meaning
M4203
0
Specified spindle active
1
Error code in W1022
W1022
2
Invalid spindle number
6
M4157 = 1 (RESTORE POSITION active)
20
Module was called in a spawn job or submit job
21
Missing strobe in M4176 = 1
Spindle
6 – 207