Error message
C000 No data exchange
with MCU
C001 Undefined error
C002 MCU command
invalid
C003 MCU/CCU
system clock mismatch
C004 Undefined
interrupt
C005 Unknown
hardware identifier
C006 I-CTRL
communication: TIME
C007 DC-link voltage
too low
C008 I-CTRL
communication:
QUEUE
C009 Stack overflow
C00A PWM triangular
signal error
C00B Too little main
memory
C00C LSV2, incorrect
number of data
10 – 10
Cause
n
Communication with the
MCU was interrupted.
n
An internal software
error has occurred.
n
Internal software error.
n
Internal software error.
n
Hardware error (quartz
generator).
n
Software error.
n
Software error.
n
Hardware error:
Disturbance results in
internal interrupt.
n
Software does not fit the
hardware.
n
Hardware defective.
n
Communication error
between speed and
current controllers.
n
Line power interrupted.
n
Inverter defective.
n
Communication error
between speed and
current controllers.
n
Internal software error.
n
Hardware error:
Triangular signal does
not oscillate or it
oscillates at the wrong
frequency.
n
Internal software error.
n
The number of LSV2
data to be read is
incorrect
n
Internal software error of
the LSV2 transmitter.
Corrective action
n
Inform your service agency.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Exchange the drive control
board or processor board.
• Check software version.
n
Switch off the machine.
n
Switch on the machine.
n
Inform your service agency.
• Check software version.
• Check the grounding.
n
Inform your service agency.
• Check software version.
• Exchange drive control
board.
n
Inform your service agency.
n
Check your line power supply.
n
Inform your service agency.
• Check the inverter.
n
Inform your service agency.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Exchange drive control
board.
n
Inform your service agency.
• Check software version.
n
Check the LSV2 transmission
software.