Error message
C00D Program
checksum error
C00E Controller
software timeout
C00F Error in software
timer
C011 Softw.
synchronization err.
C012 Pos. control err.
Cycle time
C013 PWM frequency
error
C014 Interpolator,
PWM invalid
C015 Interpolator,
PWM changed
D000 DP RAM area
overlap
D100 Software error
E001 Status NR1/NR2
not equal
E002 Status NE1/NE2
not equal
E003 PLC module 9169
illegal
E006 Wrong RDY status
of spindle
February 2002
Cause
n
Internal software or
hardware error.
n
Internal software or
hardware error.
n
Internal software error.
n
Internal software error.
n
MCU is outputting
erroneous cycle time for
CCU position controller.
n
Hardware error.
n
Entered PWM frequency
in MP2180 lies outside
the permissible input
range.
n
Invalid relation between
interpolator clock and
PWM frequency.
n
Interpolator clock or
PWM frequency was
changed.
n
An internal software
error has occurred.
n
An internal software
error has occurred.
n
NR2 input incorrectly
connected.
n
Internal software error.
n
NE2 input incorrectly
connected.
n
Internal software error.
n
PLC Module 9169 in
safety-oriented software
(illegal).
n
Internal software error.
n
Cabling to inverter
defective.
n
Spindle not connected
(spindle release relay).
n
Inverter defective.
DSP Error Messages
Corrective action
n
Inform your service agency.
• Check software version.
• Exchange drive control
board.
n
Inform your service agency.
• Check software version.
• Exchange drive control
board.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check machine parameter
MP7600.x.
• Exchange drive control
board.
n
Inform your service agency.
• Check MP2180.
n
Change the relation between
interpolator clock and PWM
frequency.
n
For possible relations, see the
User's Manual.
n
Restart the control.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check software version.
n
Inform your service agency.
• Check the wiring.
• Check software version.
n
Inform your service agency.
• Check the wiring.
• Check software version.
n
Inform your service agency.
• Check the PLC program.
• Check software version.
n
Inform your service agency.
• Check the inverter and
cabling.