Message for power
interruption

7.1.2 Color Setting

February 2002
After the control powers up, the Power interrupted message appears.
7
Press the CE key to acknowledge this message and compile the PLC
program.
With MP7212 you can suppress this message, e.g. for unattended operation.
MP7212
Power interrupted message
Input:
0: Acknowledge the Power interrupted message with CE key
1: Power Interrupted message does not appear
The colors of the display unit can be defined by machine parameters.
The following color settings cannot be changed:
n
HEIDENHAIN logo after machine switch-on (standard color)
n
Error message for invalid machine parameters (red)
n
Blinking error message (red)
n
Plan view in the graphic display (blue)
n
Cursor (inverse)
You define the desired color by mixing the basic colors red, green and blue.
Every basic color has 256 difference stages of intensity. The input values for
color setting are byte-oriented. HEIDENHAIN recommends hexadecimal
input.
Color
Red
Adjustment
Rough
HEX ranges
0 to F
Input for
3
yellow: $0....
The colors can also be poorly adjusted (e.g. red error message on red
background). HEIDENHAIN therefore supplies the controls with a standard
color setting, which is suggested by the control during creation of the MP list.
To configure the screen saver:
7
Enter in MP7392 the time in minutes after which the screen saver should
activate itself. Enter 0 to disable the screen saver.
MP7350
Window frames
MP7351
Error messages
MP7352
"Machine" operating mode display
MP7352.0
Background
MP7352.1
Text for operating mode
MP7352.2
Dialog
MP7353
"Programming" operating mode display
MP7353.0
Background
MP7353.1
Text for operating mode
MP7353.2
Dialog
Display and Operation
Green
Fine
Rough
Fine
0 to F
0 to F
0 to F
9
3
9
Blue
Rough
Fine
0 to F
0 to F
0
0
7 – 5

Advertisement

Table of Contents
loading