6 – 162
MP1150.1
Time period for which the monitoring function is to remain
off after the fast PLC input defined in MP4130.0 is set
Input:
0 to 65.535 [s]
Recommended: 0.2 to 0.5
MP4130.0
Number of the high-speed PLC input for switching off the
monitoring functions
Input:
0 to 255 [no. of the PLC input]
The inputs of the PL 4xx B may not be used!
MP4131.0
Activation criterion for fast PLC input for switching off the
monitoring functions
Input:
0: Activation at low level
1: Activation at high level
W522
Enabling the high-speed PLC inputs
Bit 0: Fast PLC input is defined in
MP4130.0 for switching off the
monitoring functions
Set
PLC
HEIDENHAIN Technical Manual iTNC 530
Reset
PLC