6.11.10 Status of HEIDENHAIN Inverters

February 2002
Status information of the HEIDENHAIN inverters can be read with Module
9066.
Module 9066 Status of HEIDENHAIN inverter
Call:
PS
B/W/D/K <>Code>
0: HEIDENHAIN inverter
CM
9066
PL
B/W/D
<>Status information>
Bit 0: No function
Bit 1: DC-link voltage too high (ERR.UZ.GR)
Bit 2: Heat sink temperature too high (ERR.TEMP)
Bit 3: Short-circuit of a motor phase with U
Bit 4: DC-link current too high (ERR.IZ.GR)
Bit 5: Power supply unit not ready (RDY.PS)
Bit 6: Leakage current too high (ERR.ILEAK)
Error detection:
Marker
Value
Meaning
M4203
0
Status has been read
1
Error code in W1022
W1022
2
Invalid code
24
Module was called in a spawn job or submit job
Monitoring Functions
(AXISFAULT)