Display/delete PLC
soft key
Select/deselect PLC
soft keys and PLC
windows
February 2002
7
Procedure for displaying/deleting a PLC soft key

Module 9201 Display/delete PLC soft key

If no PLCSOFTK.SYS file exists, or if the specified line does not exist, no soft
key is generated. In an existing PLC soft-key level, the soft key is displayed/
deleted at the specified position.
Can only be called from the sequential program.
Call:
PS
B/W/D/K <Soft-key number (line no./delete)>
0: Line no.
–1: Delete soft key
PS
B/W/D/K <Position no.>
0 to 31
PS
B/W/D/K <Soft-key mode>
0: Soft key for displayed PLC window
1: Soft key in current operating mode
2: Append soft key to NC soft key
CM
9201
Error detection:
Marker
Value
Meaning
M4203
0
No error
1
Error code in W1022
W1022
1
Transfer parameter out of value range
2
Line nr. < –1
24
Module was called in a submit job

Module 9202 Select/deselect PLC soft keys and PLC windows

With this Module 9202 you activate the display with PLC windows or the PLC
soft-key display. This module works like the screen management key.
Call:
PS
B/W/D/K <Display mode>
0: PLC soft key/window deselected
1: Small PLC soft key/window deselected
2: Large PLC soft key/window deselected
3: Large PLC soft key/window selected while table editor is
active
CM
9202
Error detection:
Marker
Value
Meaning
M4203
0
No error
1
Error code in W1022
W1022
1
Transfer parameter out of value range
PLC Soft Keys
7 – 15