6.11.12 Status of HEIDENHAIN power modules

922
Module 9066 is used to determine the status information of the HEIDENHAIN
power supply unit.

Module 9066 Status of HEIDENHAIN supply unit

Call:
PS
B/W/D/K <Code for hardware components>
0: HEIDENHAIN supply unit
1: Serial number of the SIK
2: I2t early warning
3: I2t monitoring
4: Error of analog part
CM
9066
PL
B/W/D
<Status information>
Code 0: HEIDENHAIN power supply unit
Bit 0: Not used
Bit 1: DC-link voltage too high
Bit 2: Heat sink temperature too high
Bit 3: Short-circuit of a motor phase with Uz
Bit 4: DC-link current too high
Bit 5: Power supply unit not ready
Bit 6: Leakage current too high
Code 1: Serial number of the SIK
Codes 2 to 4: Axis masks
Error code:
Marker
Value
Meaning
M4203
0
Status ascertained
1
Error code in W1022
W1022
2
Invalid code
24
Module was called in a spawn job or submit job
The HEIDENHAIN power supply units have several status signals which lead
to error messages on the control. MP2195 is used to suppress the error
message for each status signal.
HEIDENHAIN does not recommend suppressing the error messages from the
power supply units. If you are using a UE 2xx, the signals must be suppressed
because the UE 2xx compact inverter does not provide these signals.
HEIDENHAIN Technical Manual iTNC 530 HSCI