The I/O-Force List - HEIDENHAIN iTNC 530 HSCI Technical Manual

Hide thumbs Also See for iTNC 530 HSCI:
Table of Contents

Advertisement

9.1.5 The I/O-FORCE LIST

Add operands
to I/O -FORCE LIST
1674
With the I/O-Force List you create a table in which the status of selected
inputs and outputs is written based on the process image.
Danger
The I/O-FORCE LIST can overrule safety-relevant monitoring operations as
well as any inputs and outputs in the PLC program! Activation of the I/O-
FORCE LIST can therefore only be done with extreme care. Also make sure
that hanging axes are supported.
Meaning of the columns in I/O-FORCE LIST:
SYMBOL: Symbolic address of the operand
Absolute address of the operand
ADDR:
Content of the operand
VALUE:
COMMENT: Comment for the operand
Press the WATCH LIST or TABLE soft key in the PLC Programming operating
mode.
With WATCH LIST: In the WATCH LIST, select the line with the desired
operand (input or output). You may also select the operand via the SYMBOL
LIST first.
With TABLE: In the TABLE, select the desired operand via soft key and the
keyboard arrow keys.
Press the ADD TO I/O-FORCE LIST soft key.
The operand is written to the I/O-FORCE LIST, and a message confirming the
transfer of the operand to the I/O-FORCE LIST appears.
Note
When using the I/O-FORCE LIST, remember that:
If an operand is entered and the I/O-FORCE LIST is activated via soft key,
then this operand is marked in color in the TABLE, and the SET and RESET
soft keys have no meaning.
The green error message I/O-Force is output in the PLC Programming
mode of operation if the I/O-FORCE LIST is active.
HEIDENHAIN Technical Manual iTNC 530 HSCI

Advertisement

Table of Contents
loading