3.7.8 Switching Outputs 24 Vdc for the PLC

Transistor outputs with current limiting
Min. output voltage for "1" signal
Nominal operating current per output
·
Permissible load: resistive load; inductive load only with quenching diode parallel to the
inductance.
·
No more than one output may be shorted on the logic unit at any time. Short circuit of one
output does not cause an overload.
·
No more than half the PLC outputs may be driven at the same time (simultaneity factor 0.5).
Address
No. of outputs Device
O0 to O30
31
O0 to O7
O32 to O62
31
O64 to O94
31
O48 to O62
15
X44 Power Supply for the outputs of the LE
Terminal
Assignment
1
+24 Vdc can be switched off via EMERGENCY
STOP
2
+24 Vdc cannot be switched off via EMERGENCY
STOP
3
0V
Power Supply for the outputs on the PL 410 B/ PL 405 B
Terminal
Assignment
X9
0 V
X10
+24 Vdc power supply for logic and for control-is-ready signal
X11
+24 Vdc power supply for outputs
X12
+24 Vdc power supply for outputs
X13
+24 Vdc power supply for outputs
X14
+24 Vdc power supply for outputs
For connecting the PL 410 B to the LE, see section 3.9.14.
3–20
TNC 370 D
Logic unit
3 V below supply voltage
0.125 A with simultaneity
factor of 0.5
Logic unit X41 (PLC output)
Logic unit X46 (machine operating panel)
First PL 410 B
Second PL 410 B
PL 405 B
Mounting and Electrical Installation
PL 410 B/PL 405 B
1.2 A with simultaneity
factor of 0.5;
2 A with max. current
consumption of 20 A
PLC outputs
O0 to O23
O24 to O30
1st PL 410 B
2nd PL 410 B
Pl 405 B
O32 to O39
O64 to O71
O40 to O47
O72 to O79
O48 to O55
O80 to O87
O56 to O62
O88 to O94
July 02