C: Tuning; C1: Accel And Decel Times; C2: S-Curve Characteristics - YASKAWA GA700 Technical Manual

High performance type; 200 v class: 0.4 to 110 kw; 400 v class: 0.4 to 355 kw
Hide thumbs Also See for GA700:
Table of Contents

Advertisement

10.6

C: Tuning

C1: Accel and Decel Times

No.
Name
(Hex.)
C1-01
Acceleration Time
1
(0200)
RUN
C1-02
Deceleration Time
1
(0201)
RUN
C1-03
Acceleration Time
2
(0202)
RUN
C1-04
Deceleration Time
2
(0203)
RUN
C1-05
Acceleration Time
3
(0204)
RUN
C1-06
Deceleration Time
3
(0205)
RUN
C1-07
Acceleration Time
4
(0206)
RUN
C1-08
Deceleration Time
4
(0207)
RUN
C1-09
Fast Stop Time
(0208)
C1-10
Accel/Decel Time
Setting Units
(0209)
C1-11
Accel/Decel Time
Switchover Freq
(020A)

C2: S-Curve Characteristics

No.
Name
(Hex.)
C2-01
S-Curve Time @
Start of Accel
(020B)
C2-02
S-Curve Time @
End of Accel
(020C)
YASKAWA ELECTRIC SIEP C710617 01B YASKAWA AC Drive GA700 Technical Manual
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time it takes to accelerate from zero to the maximum output
frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time it takes to decelerate from the maximum output
frequency to zero.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to accelerate from 0 to maximum frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to decelerate from maximum frequency to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to accelerate from 0 to maximum frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to decelerate from maximum frequency to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to accelerate from 0 to maximum frequency.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the time to decelerate from maximum frequency to 0.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the deceleration time for the drive to trigger the Fast Stop.
Note:
Rapid deceleration can trigger ov [Overvoltage]. The drive
output shuts off when ov is detected and the motor coasts. Set an
appropriate Fast Stop time to C1-09 to avoid motor coasting and
to ensure that the motor stops quickly and safely.
V/f
CL-V/f
OLV
CLV
AOLV
Selects the setting units for C1-01 to C1-08 [Acceleration Time 1
through Deceleration Time 4], C1-09 [Fast Stop Time], L2-06 [KEB
Deceleration Time], and L2-07 [KEB Acceleration Time].
0 : 0.01 s units
1 : 0.1 s units
V/f
CL-V/f
OLV
CLV
AOLV
Sets the frequency at which acceleration and deceleration times are
automatically changed.
Description
V/f
CL-V/f
OLV
CLV
AOLV
Sets the S-curve time to the time to start acceleration.
V/f
CL-V/f
OLV
CLV
AOLV
Sets the S-curve time to the time to complete acceleration.
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM
OLV/PM AOLV/PM CLV/PM EZOLV
OLV/PM

10.6 C: Tuning

Default
Ref.
(Range)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
645
(0.0 - 6000.0 s)
10.0 s
646
(0.0 - 6000.0 s)
10.0 s
646
(0.0 - 6000.0 s)
10.0 s
646
(0.0 - 6000.0 s)
1
646
(0, 1)
Determined by A1-
647
02
(0.0 - 590.0 Hz)
Default
Ref.
(Range)
Determined by A1-
648
02
(0.00 to 10.00 s)
0.20 s
648
(0.00 - 10.00 s)
411
10

Advertisement

Table of Contents
loading

Table of Contents