3. If an expansion enclosure is installed, remove it (see "Removing an expansion
4. Remove the PCIe riser-card assembly, if one is installed (see "Removing a PCIe
5. Locate the battery on the system board (see "System-board connectors" on
6. Use one finger to press the top of the battery clip away from the battery. The
7. Use your thumb and index finger to lift the battery from the socket.
8. Dispose of the battery as required by local ordinances or regulations (see the

Installing the battery

The following notes describe information that you must consider when you are
replacing the battery in the system-board tray.
v You must replace the battery with a lithium battery of the same type from the
v To order replacement batteries, call 1-800-426-7378 within the United States, and
v After you replace the battery, you must reconfigure the system-board tray and
v To avoid possible danger, read and follow the following safety statement.
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
v Throw or immerse into water
v Heat to more than 100°C (212°F)
v Repair or disassemble
Dispose of the battery as required by local ordinances or regulations.
To install the battery, complete the following steps.
138
System x iDataPlex dx360 M2: Problem Determination and Service Guide
enclosure from a system-board tray" on page 131); otherwise, remove the
system-board tray cover (see "Removing the system-board tray cover" on page
125).
riser-card assembly from the system-board tray" on page 171).
page 11).
battery pops up when it is released.
Environmental Notices and User's Guide on the IBM Documentation CD for
information about disposing of the battery).
same manufacturer.
1-800-465-7999 or 1-800-465-6666 within Canada. Outside the U.S. and
Canada, call your IBM marketing representative or authorized reseller.
reset the system date and time.