Table 3. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
Memory uncorrectable error
detected for DIMM All
DIMMs on Memory
Subsystem All DIMMs.
Memory uncorrectable error
detected for DIMM One of
the DIMMs on Memory
Subsystem One of the
DIMMs.
96
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Severity
Description
Info
DIMM disabled
Info
DIMM disabled
Action
1. Make sure the DIMM is installed
correctly (see "Installing a
memory module" on page 164).
2. If the DIMM was disabled
because of a memory fault
(memory uncorrectable error or
memory logging limit reached),
follow the suggested actions for
that error event and restart the
server.
3. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this memory event. If no
memory fault is recorded in the
logs and no DIMM connector
error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).
1. Make sure the DIMM is installed
correctly (see "Installing a
memory module" on page 164
for memory population).
2. If the DIMM was disabled
because of a memory fault
(memory uncorrectable error or
memory logging limit reached),
follow the suggested actions for
that error event and restart the
server.
3. Check the IBM support website
for an applicable retain tip or
firmware update that applies to
this memory event. If no
memory fault is recorded in the
logs and no DIMM connector
error LED is lit, you can
re-enable the DIMM through the
Setup utility or the Advanced
Settings Utility (ASU).

Advertisement