Removing The 3U Chassis Fan Assembly - IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

Removing the 3U chassis fan assembly

To remove the 3U chassis fan assembly, complete the following steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If the 3U chassis is installed in an iDataPlex rack, remove it (see "Removing a
3. Remove the top cover (see "Removing the 3U chassis top cover" on page 136).
4. Remove the storage-riser-card assembly and ServeRAID SAS controller (see
5. Slide the retention bracket to release it and remove the bracket from the
6. Grasp the tab at each end of the fan assembly and lift it out of the chassis.
7. If you are instructed to return the fan assembly, follow all packaging instructions,
on page 123.
3U chassis from a Type 7825 iDataPlex rack" on page 190).
"Removing a storage-riser-card assembly, ServeRAID SAS controller, and
battery cable interposer card from a 3U chassis" on page 181).
chassis.
and use any packaging materials for shipping that are supplied to you.
Chapter 5. Removing and replacing server components
149

Advertisement

Table of Contents
loading

Table of Contents