Removing an expansion enclosure from a system-board tray

To remove an expansion enclosure from a system-board tray, complete the
following steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. If the system-board tray is installed in a chassis, remove it (see "Removing the
3. Carefully set the system-board tray on a flat, static-protective surface.
4. Pull the release latch on each side of the expansion enclosure outward; then,
5. Make a note of where the cables are attached; then, if necessary, disconnect
6. Lift the expansion enclosure from the system-board tray and set the expansion
on page 123.
system-board tray from a 2U chassis" on page 126).
rotate the expansion enclosure approximately 30 degrees to a partially open
position.
them.
enclosure on a flat, static-protective surface.