Installing The System-Board Tray In A 3U Chassis - IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

10. Push on the back edge of the system-board tray from inside the 3U chassis
11. Pull the system-board tray out of the 3U chassis and set it on a flat,

Installing the system-board tray in a 3U chassis

To install the system-board tray in a 3U chassis, complete the following steps.
5. Press on the two release latches at the top-rear edge of the top-cover
assembly; then, slide the top-cover assembly toward the rear of the 3U chassis
and remove it.
6. Remove the storage-riser-card assembly and ServeRAID SAS controller (see
"Removing a storage-riser-card assembly, ServeRAID SAS controller, and
battery cable interposer card from a 3U chassis" on page 181).
7. Slide and release the retention bracket that secures the fan assembly and
remove the bracket from the chassis.
8. Lift up on both fan-assembly handles and remove the fans from the 3U
chassis.
9. Note the cable routing and connection locations; then, disconnect the cables
that connect the system-board tray to the 3U chassis.
and slide the system-board tray forward.
static-protective surface.
Chapter 5. Removing and replacing server components
129

Advertisement

Table of Contents
loading

Table of Contents