IBM System x iDataPlex dx360 M2 Problem Determination And Service Manual page 97

Hide thumbs Also See for System x iDataPlex dx360 M2:
Table of Contents

Advertisement

Table 3. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
An SM BIOS Uncorrectable
CPU complex error for
Processor CPU n Status
has asserted.
(n = microprocessor number)
Attempting to %1 server %2
by user %3.
(%1 = Power Up, Power
Down, Power Cycle, or
Reset;
%2 = IBM_ComputerSystem.
ElementName; %3 = user
ID)
Certificate Authority %1 has
detected a %2 Certificate
Error. (%1 = IBM_Certificate
Authority.CADistinguished
Name; %2 =
CIM_PublicKeyCertificate.
ElementName)
DHCP setting changed to
%1 by user %2. (%1 =
DHCP addressing mode,
%2 = user ID)
Severity
Description
Error
An SMBIOS uncorrectable CPU
complex error has asserted.
Info
A user has used the IMM to
perform a power function on the
server.
Error
A problem has occurred with the
SSL Server, SSL Client, or SSL
Trusted CA certificate that has been
imported into the IMM. The
imported certificate must contain a
public key that corresponds to the
key pair that was previously
generated by the Generate a New
Key and Certificate Signing
Request link.
Info
A user has changed the DHCP
mode.
Action
1. Check for a UEFI firmware
update.
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part of
a cluster solution, verify that the
latest level of code is supported
for the cluster solution before
you update the code.
2. Make sure that the installed
microprocessors are compatible
with each other (see "Installing
a microprocessor and heat sink"
on page 199 for information
about microprocessor
requirements).
3. (Trained service technician only)
Reseat microprocessor n.
4. (Trained service technician only)
Replace microprocessor n.
(n = microprocessor number)
No action; information only.
1. Make sure that the certificate
that you are importing is
correct.
2. Try importing the certificate
again.
No action; information only.
Chapter 3. Diagnostics
81

Advertisement

Table of Contents
loading