Table 3. Integrated management module error messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing," on page 109 to determine which components are customer replaceable
units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Message
Numeric sensor Domain B
Temp2 going high (upper
non-critical) has asserted.
Numeric sensor Fan n Tach
going low (lower critical) has
asserted.
(n = fan number)
Numeric sensor Planar 12V
going high (upper critical)
has asserted.
Numeric sensor Planar 12V
going low (lower critical) has
asserted.
Numeric sensor Planar 3.3V
going high (upper critical)
has asserted.
Numeric sensor Planar 3.3V
going low (lower critical) has
asserted.
Numeric sensor Planar 5V
going high (upper critical)
has asserted.
Numeric sensor Planar 5V
going low (lower critical) has
asserted.
Numeric sensor Planar
VBAT going low (lower
critical) has asserted.
Numeric sensor Planar
VBAT going low (lower
non-critical) has asserted.
OS Watchdog response %1
by %2.
(%1 = Enabled or Disabled;
%2 = user ID)
98
System x iDataPlex dx360 M2: Problem Determination and Service Guide
Severity
Description
Warning
An upper non-critical sensor going
high has asserted.
Error
A lower critical sensor going low
has asserted.
Error
An upper critical sensor going high
has asserted.
Error
A lower critical sensor going low
has asserted.
Error
An upper critical sensor going high
has asserted.
Error
A lower critical sensor going low
has asserted.
Error
An upper critical sensor going high
has asserted.
Error
A lower critical sensor going low
has asserted.
Error
A lower critical sensor going low
has asserted.
Warning
A lower non-critical sensor going
low has asserted.
Info
A user has enabled or disabled an
OS Watchdog.
Action
Make sure that the fans are
operating, that there are no
obstructions to the airflow, that the
air baffles are in place and correctly
installed, and that the server cover
is installed and completely closed.
1. Turn off the server and
disconnect it from power.
2. Reseat the failing fan assembly.
3. Replace the failing fan
assembly.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
(Trained service technician only)
Replace the system board.
Replace the 3V battery.
Replace the 3V battery.
No action; information only.