2. If the chassis contains a system-board tray that is operating, shut down the
3. Remove any installed system-board trays (see "Removing the system-board tray
4. Remove the two screws that secure the chassis to the rack; then, pull the
5. If you are replacing a damaged chassis, remove the fan assembly and power
6. If you are instructed to return the 2U chassis, follow all packaging instructions,

Installing the 2U chassis in a Type 7825 iDataPlex rack

To install the 2U chassis in a Type 7825 iDataPlex rack, complete the following
steps.
1. If you are installing a new chassis, install the power supply and fan assembly
2. Install the chassis on the rails; then, install the two screws to secure the chassis
3. Install any system-board trays that you removed when you removed the chassis
operating system; then, press the power-control button to turn off the
system-board tray (see "Turning off the system-board tray" on page 10 for more
information).
from a 2U chassis" on page 126).
chassis forward, lift the chassis out of the iDataPlex rack, and set it on a flat,
static-protective surface.
supply from the chassis, and place them on a static-protective surface or install
them in the new chassis (see "Removing the 2U chassis fan assembly" on page
133 and "Removing a power supply from a 2U chassis" on page 173).
and use any packaging materials for shipping that are supplied to you.
that you removed from the old chassis (see "Installing a power supply in a 2U
chassis" on page 174 and "Installing the 2U chassis fan assembly" on page
134).
to the rack.
(see "Installing the system-board tray in a 2U chassis" on page 127).