Power Supply Trouble - Konica Minolta BIZHUB 163 Service Manual

Hide thumbs Also See for BIZHUB 163:
Table of Contents

Advertisement

Field Service Ver. 1.0 Apr. 2007

15. Power supply trouble

15.1 The copier does not turn ON
Step
A malfunction code appears when the power
1
switch is turned ON.
The malfunction is temporarily reset when the
2
power switch is turned OFF and ON with the
Stop key held down.
Power supply voltage check
<Check procedure>
Check voltage across pins of power supply unit
(DCPU) when the power switch is turned ON.
3
• Voltage across CN1DCPU-1 and CN1DCPU-
2 AC0 V when the power switch is OFF
Rated AC voltage when the power switch is
turned ON
Check of output of DC24 V to MFP board
(copier: MFPB)
<Check procedure>
Check voltage across a MFP board (MFPB) pin
4
and GND when the power switch is turned ON.
• Voltage across P110MFPB-1 and GND
• Voltage across P110MFPB-2 and GND
DC0 V when the power switch is OFF
DC24 V when the power switch is turned ON
Check of output of DC24 V to printer control
board (PRCB)
<Check procedure>
Check voltage across a printer control board
5
(PRCB) pin and GND when the power switch is
turned ON.
• Voltage across PJ2PRCB-2 and GND
DC0 V when the power switch is OFF
DC24 V when the power switch is turned ON
Check of output of DC 5 V to printer control
board (PRCB)
<Check procedure>
Check voltage across a printer control board
6
(PRCB) pin and GND when the power switch is
turned ON.
• Voltage across PJ6PRCB-9 and GND
DC0 V when the power switch is OFF
DC24 V when the power switch is turned ON
Check of output of DC5 V to control panel
<Check procedure>
Check voltage across a MFP board (MFPB) pin
7
and GND when the power switch is turned ON.
Voltage across P102MFPB-1 and GND
DC0 V when the power switch is OFF
DC5 V when the power switch is turned ON
Check
15. Power supply trouble
Result
Action
YES
• Go to step 2.
NO
• Go to step 3.
• Perform the troubleshooting pro-
YES
cedure according to the malfunc-
tion code.
• Check wall outlet for voltage.
NO
• Check power cord for continuity.
• Check power switch.
• Check front door interlock switch
(S3).
• Check right door interlock switch
NO
(S4).
• Change power supply unit
(DCPU).
• Check front door interlock switch
(S3).
• Check right door interlock switch
NO
(S4).
• Change power supply unit
(DCPU).
• Change power supply unit
NO
(DCPU)
• Check MFP board (MFPB).
• Change printer control board
NO
(PRCB).
• Change power supply unit
(DCPU)
YES
• Change control panel.
173

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 211Bizhub 220Bizhub 163

Table of Contents