Adjust - Konica Minolta BIZHUB 163 Service Manual

Hide thumbs Also See for BIZHUB 163:
Table of Contents

Advertisement

10. Service Mode
AH.GDI TIMEOUT
Functions
• To specify the time for timeout when data from PC is interrupted during GDI printing.
Use
Setting/
• The default setting is 6.
Procedure
0 (5 sec.) 1 (10 sec.) 2 (20 sec.) 3 (30 sec.) 4 (40 sec.) 5 (50 sec.) "6 (60 sec.)"
10.3.2

ADJUST

A. PRN MAIN REGIST
Functions
• To adjust by varying the starting position of image writing in the main scanning direc-
tion.
Use
• Used when the image on the copy deviates in the main scanning direction.
• Used when the PH unit has been replaced.
Setting/
Procedure
• Adjustment instructions
If width A on the test pattern is longer than the specifications, decrease the setting
value.
If width A on the test pattern is shorter than the specifications, increase the setting
value.
Adjustment
Procedure
1. Load the tray 1 with A4 paper.
2. Enter function of the Service Mode.
3. Select [PRN TEST PATTERN] and then [TEST PATTERN1]. Then, press the Start
key.
This will produce a test pattern.
4. Check to see if width A on the test pattern falls within the specified range.
If width A falls outside the specified range, perform the following steps to make an
adjustment.
5. Select [PRN MAIN REGIST] of [ADJUST].
6. Using [ ▲ / ▼ ] key, select the appropriate setting value.
7. Press the OK key to validate the setting value selected in step 6.
8. If a single adjustment procedure does not successfully bring width A into the speci-
fied range, repeat steps 5 through 7.
126
60 (-4.0 mm) to 140 (+4.0 mm)
(1 step: 0.1 mm)
A
A09AF3C504DA
Field Service Ver. 1.0 Apr. 2007
Adjust so that width A on the test pattern pro-
duced falls within the specified range.
Specifications
20 ± 2.0 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 211Bizhub 220Bizhub 163

Table of Contents