Field Service Ver. 1.0 Apr. 2007
8.6.7
SOFT SWITCH: #07
Bit
Designation
No.
Dial tone or busy tone
8
detection
7
PSTN/PBX setting
6
PBX dial tone detect
5
Dial mode select
4
3
2
Tx level select for PSK/
FSK
1
Function
0: Disable
1: Enable - Detect dial tone before dial
0: PSTN
1: PBX - Select PBX line type
0: Not to detect dial tone before pre-fix number
1: Detect dial tone before the pre-fix number in PBX
mode
0: DTMF - PB
1: Pulse - DP
Level (dBm) -17 -16 -15 -14 -13 -12 -11 -10
Bit 4
0
0
Bit 3
0
0
Bit 2
0
0
Bit 1
0
1
Level (dBm)
-9
-8
-7
Bit 4
1
1
Bit 3
0
0
Bit 2
0
0
Bit 1
0
1
8. Soft Switch Set
0
0
0
0
0
0
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
-6
-5
-4
-3
-2
1
1
1
1
1
1
0
0
1
1
1
1
1
1
0
0
1
1
0
1
0
1
0
1
Initial
Setting
Bit
HEX
0
0
0
0
0
1
0
0
8
0
65

Hide quick links: