13.3.3
Misfeed at the manual bypass tray paper feed section
A. Detection timing
Type
Manual bypass tray
• The leading edge of the paper does not unblock the registration sensor (PS1)
paper feed section
misfeed detection
• The registration sensor (PS1) is not blocked even after the lapse of a given
Size error detection
• The registration sensor (PS1) is blocked before the lapse of a given period of
Paper left at the
• The paper set sensor/bypass (PS2) is blocked at timing when the power switch
manual bypass tray
paper feed section
B. Action
Registration sensor (PS1)
Paper feed solenoid/bypass (SD2)
Step
1
Initial checks
2
PS1 sensor check
3
SD2 operation check
4
PS2 sensor check
5
Replace PRCB
even after the lapse of a given period of time after the paper feed solenoid/
bypass (SD2) has been energized.
period of time after the paper has unblocked the PS1.
time.
is turned ON, the cover is opened and closed, or a paper misfeed or malfunc-
tion is reset.
Relevant electrical components
Operations
Description
Paper set sensor/bypass (PS2)
Printer control board (PRCB)
WIRING DIAGRAM
Control signal
PRCB PJ17PRCB-3 (ON)
PRCB PJ12PRCB-2 (REM)
PRCB PJ12PRCB-5 (ON)
13. Jam display
Location
(Electrical compo-
nents)
C-5
K-18
K-17
157