10.2 Error Code; Reception - Konica Minolta BIZHUB 163 Service Manual

Hide thumbs Also See for BIZHUB 163:
Table of Contents

Advertisement

10. Fax Error

10.2 Error Code

10.2.1

Reception

Code
0001
No G3 signal received within 35 sec. in manual receive mode.
0003
Received DIS after sending DIS signal.
0004
Received DCN after sending DTC signal.
0006
Detect busy tone within receiving phase B.
0009
Can not receive any signal within 35 sec. in manual polling mode.
0010
Received DCN signal after sending DTC signal in polling RX.
0011
Can not receive any correct response after sending three DTC signals.
0012
Remote side Password does not match in polling RX/our side no file to be polled.
0013
Can not receive carrier signal within 6 sec. after sending CFR in data phase C.
0014
Can not receive T.30 signal after sending FTT signal.
0015
Line polarity change within receiving phase B to D.
0016
Receive DCN signal after sending FTT signal.
0017
Can not receive any response from remote side after sending type of xxx_EOM signal.
0018
Can not detect energy within 6 sec. after sending FTT command.
0019
Received DCN signal after sending CFR signal.
001A
No energy on line over 6 sec. within phase C before any corrected ECM frame.
001D
Detect flag but noting after CER.
0020
Can not correct frame within 6 sec., or in non-ECM mode, one decoding line over 6 sec.
0021
File full
Owing to noise interference on the line, receiving side can't receive correct data within spec-
0022
ified time (no ECM).
- Received "Remote monitoring password" error in RSD.
0023
- The Customer machine has updated the firmware now.
- The Service Tech. Rep. updated remote machine firmware by RSD.
- TX and RX machines both have different "machine ID (FAX model ID)" code in RSD.
0024
- The Customer machine has updated the firmware now.
- The Service Tech. Rep. updated remote machine firmware by RSD
- TX and RX machines have different "company ID (FAX machine maker ID)" code in RSD.
0025
- The Customer machine has updated the firmware now.
- The Service Tech. Rep. updated remote machine firmware by RSD
- Remote monitor level error. Remote side can't access in RSD.
0026
- The Customer machine has updated the firmware now.
- The Service Tech. Rep. updated remote machine firmware by RSD
0027
RSD connect failure due to user incorrect operation or machine error.
0029
Mailbox password not programmed or matched for mailbox receiving.
002A
Line Problem
0030
Did not receive any signal within 6 sec.at phase D.
0031
Received incorrect signal at phase D (not EOP, MPS, EOM, DCS PPS_Q, PPS_Q, etc.).
0032
Did not receive carrier signal within 6 sec.after sending MCF. or RTP, RTN signal.
0033
Received DCN signal at phase D within pages (not last page).
In non-ECM mode, when machine already received the data but next line data doesn't
0039
receive within 13.1 seconds.
118
Field Service Ver. 1.0 Apr. 2007
Possible Causes of Error.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bizhub 211Bizhub 220Bizhub 163

Table of Contents