16. Power supply trouble

16. Power supply trouble

16.1 The copier does not turn ON

Step
A malfunction code appears when the Power
1
Switch is turned ON.
The malfunction is temporarily reset when the
2
Power Switch is turned OFF and ON with the Stop
key held down.
Power supply voltage check
<Check Procedure>
Check voltage across pins of DC Power Supply
(PU1) when the Power Switch is turned ON.
3
• Voltage across CN1PU1-1 and CN1PU1-2
AC0 V when the Power Switch is OFF
Rated AC voltage when the Power Switch is
turned ON
Check of output of DC24 V to Control Board
(copier: PWB-C)
<Check Procedure>
Check voltage across a Control Board (copier:
PWB-C) pin and GND when the Power Switch is
4
turned ON.
• Voltage across P110C/C-1 and GND
• Voltage across P110C/C-2 and GND
DC0 V when the Power Switch is OFF
DC24 V when the Power Switch is turned ON
Check of output of DC24 V to Master Board
(copier: PWB-A)
<Check Procedure>
Check voltage across a Master Board (copier:
5
PWB-A) pin and GND when the Power Switch is
turned ON.
• Voltage across PJ2A-2 and GND
DC0 V when the Power Switch is OFF
DC24 V when the Power Switch is turned ON
Check of output of DC 5 V to Master Board
(copier: PWB-A)
<Check Procedure>
Check voltage across a Master Board (copier:
6
PWB-A) pin and GND when the Power Switch is
turned ON.
• Voltage across PJ6A-9 and GND
DC0 V when the Power Switch is OFF
DC24 V when the Power Switch is turned ON
Check of output of DC5 V to control panel (UN2)
<Check Procedure>
Check voltage across a Control Board (copier:
PWB-C) pin and GND when the Power Switch is
7
turned ON.
• Voltage across P102C/C-1 and GND
DC0 V when the Power Switch is OFF
DC5 V when the Power Switch is turned ON
152
Check
Field Service Ver. 1.0 Apr. 2005
Result
Action
YES
• Go to step 2.
NO
• Go to step 3.
• Perform the troubleshooting
YES
procedure according to the mal-
function code.
• Check wall outlet for voltage.
NO
• Check power cord for continuity.
• Check Power Switch.
• Check Front Door Interlock
Switch (S3).
• Check Right Door Interlock
NO
Switch (S4).
• Change DC power Supply
(PU1).
• Check Front Door Interlock
Switch (S3).
• Check Right Door Interlock
NO
Switch (S4).
• Change DC power Supply
(PU1).
• Change DC power Supply
NO
(PU1).
• Check Control Board (copier:
PWB-C).
• Change Master Board (copier:
NO
PWB-A).
• Change DC power Supply
(PU1).
YES
• Change Control Panel (UN4).