Non-Service Affecting Alarms
VIMM Isolated Alarm
The VIMM Isolated alarm indicates that the specified VIMM is isolated and not
reachable by any other VIMM within the tree. This is caused by the failure of
other VIMMs, preventing a path from the main controller to the VIMM.
To clear the alarm, replace the failed VIMM(s).
VIMM Temperature Unreadable, VIMM Shut
Down Alarm
The VIMM Temperature Unreadable, VIMM Shut Down alarm indicates that the
temperature for the specified VIMM cannot be read and the VIMM has been
shut down.
To clear the alarm, replace the VIMM.
VIMM Unformatted Alarm
The VIMM Unformatted alarm indicates that the specified VIMM is unformatted,
and is thus not being used.
VIMM Voltage; VIMM Shut Down Alarm
The VIMM Voltage; VIMM Shut Down alarm indicates an over/under voltage
condition and the voltage reading just before shutdown for a specific VIMM.
To clear the alarm, replace the VIMM.
VIMM Threshold Exceeded Alarm
The VIMM Threshold Exceeded alarm indicates that a VIMM has been taken out
of service due to an exceeded monitored threshold.
Fan Running Too Slowly Alarm
The Fan Running Too Slowly alarm indicates that the specified fan is running at
a much lower speed than it should. The alarm specifies the top (
) or bottom (
)
1
2
fan tray and the fan within that fan tray:
,
, or
.
left
center
right
To clear the alarm, replace the fan tray in the system.
VMA-series Memory Array Installation and Service Guide
HP-AM456-9002A Rev 01