Displaying The Upgrade Path; Updating The System Software Factory Image - HP VMA Series Installation And Service Manual

Memory array
Hide thumbs Also See for VMA Series:
Table of Contents

Advertisement

HP-AM456-9002A Rev 01
While the system is rebooting, reboot your host server.
4.
Log back into the Memory Array when it is finished rebooting.
5.

Displaying the Upgrade Path

After setting the upgrade path, and before the system reboots, display the path
to the upgrade software.
Log into the Memory Array.
1.
Sw-upgrade
Navigate to the
2.
context system sw-upgrade
At the context prompt, type:
3.
show path
The command displays information similar to the following:
system sw-upgrade> show path
Upgrade image path = 'bob@ftp://10.10.0.15/pub/v1010_x8_p1_d.img'
Updating the System Software Factory
Image
Update the system software factory image if you have both factory and upgrade
images installed on the Memory Array and you want to make the current
upgrade image the factory image.
Copy the current firmware image into the
1.
prompt, type:
copy system sw-upgrade active factory
You are prompted to confirm. Upon confirmation, the system reboots.
2.
This procedure interrupts service.
WARNING!
VMA-series Memory Array Installation and Service Guide
Upgrading the System Software
context level. At the root prompt, type:
factory
partition. At the root
105