Chapter 5 - Operating the System via the CLI
> > set system sw-upgrade path bob@scp://10.10.0.15/home/bob_home/vtms-array-firmware-
x8-R3.4.0-15954.upg
Do you wish to download this upgrade image (Y/N)? y
Downloading...
OK
Verifying image ...
Violin S/W Upgrade Image
Header Ver.:
1
Name: R3.4.0-15954_x8ans
Created:
Tue July 10 2010 16:47:10 2009
Revision:
13208
Data Size:
15630085 Bytes = 14.91 MB
Num Parts:
4
#
PT Name
-- -- ---------- ---------- ----------
0
0
BOOTROM
1
1
CPL
2
2
OAM
3
3
MOZART
Verifying data checksum...OK
OK
Flash erase ...
Erased 32768 Kibyte @ 0 -- 100% complete.
OK
Flash copy ...
.......................................................................................
.................................done
OK
Verifying flash ...
Verifying data checksum...OK
OK
Activating upgrade ...
Updating partition information ...
Upgrade complete, 'reboot system all' for changes to take effect.
102
host_ip_addr
path
upgr_image
You are prompted to confirm the download of the upgrade software. Upon
confirmation, the upgrade software is downloaded to RAM on the main
board and then copied into the upgrade partition of flash. That partition is
then made to be the active one upon reboot.
The command displays information similar to the following:
Offset
Length
0x00000100 0x0002D60F
0x00040000 0x006FC94D
0x00740000 0x00526054
0x00C80000 0x00268005
VMA-series Memory Array Installation and Service Guide
Specifies the IP address of the host.
Specifies the path location of the upgrade file on
the host.
Specifies the file name of the upgrade image.
Make sure to use the appropriate image for your
application.