Crd 8100 1200M - Symbol PDT 8100 Series Product Reference Manual

With windows mobile 2003 software for pocket pcs
Hide thumbs Also See for PDT 8100 Series:
Table of Contents

Advertisement

CRD 8100 1200M

Table 12-4. Troubleshooting The CRD 8100-1200M
Symptom
LEDs do not light when terminal
or spare battery is inserted.
Terminal battery is not charging. Terminal was removed from
Spare battery is not charging.
Possible Cause
Cradle is not receiving power.
Terminal is not seated firmly in
the cradle.
Spare battery is not seated
firmly in the cradle.
cradle or cradle was unplugged
from AC power too soon.
Battery is faulty.
The terminal is not fully seated
in the cradle.
Battery not fully seated in
charging slot.
Battery inserted incorrectly.
Battery is faulty.
Maintenance and Troubleshooting
Action
Ensure the power cable is
connected securely to both the
cradle and to AC power.
Remove and re-insert the
terminal into the cradle,
ensuring it is firmly seated.
Remove and re-insert the spare
battery into the charging slot,
ensuring it is firmly seated.
Ensure cradle is receiving
power. Ensure terminal is
seated correctly. Confirm main
battery is charging under Start -
Settings - System - Power. If a
terminal battery is fully
depleted, it can take up to 2.5
hours to fully recharge a battery
(if the terminal is off and longer
if the terminal is operating).
Verify that other batteries
charge properly. If so, replace
the faulty battery.
Remove and re-insert the
terminal into the cradle,
ensuring it is firmly seated.
Remove and re-insert the spare
battery into the cradle, ensuring
it is firmly seated.
Ensure the contacts are facing
down and toward the back of
the cradle.
Verify that other batteries
charge properly. If so, replace
the faulty battery.
12-13