Table 12-7. Troubleshooting The VCD 8100-R001
Symptom
Terminal LED not red when
terminal is out of cradle.
Terminal LED doesn't turn
green when terminal is inserted.
Spare battery LED doesn't light
when battery is inserted.
Terminal battery is not charging. Terminal was removed from
12-24
Cause
Cradle is not receiving power
from the vehicle.
Terminal is not correctly seated
in the cradle.
Spare battery is not correctly
seated in the cradle.
cradle or cradle was unplugged
from vehicle power too soon.
Battery is faulty.
The terminal is not correctly
seated in the cradle.
Solution
Ensure the power cable is
connected securely to both the
cradle and to vehicle power.
Ensure 9-32 Vdc is present at
pin 4 of the Power Cable
Connector.
Remove and re-insert the
terminal into the cradle, making
sure it is firmly seated (see page
3). Check slot for debris.
Remove and re-insert the spare
battery into slot, making sure it
is firmly seated (see page
4).Check slot for debris.
Plug the terminal and cradle
back into the vehicle power
source. If a terminal battery
pack is fully depleted, it can take
to 2.5 hours to fully recharge a
1950 mAh battery (if the
terminal is off and longer if the
terminal is operating).
Verify that other batteries
charge properly. If so, replace
the faulty battery.
Remove and re-insert the
terminal into the cradle, making
sure it is firmly seated (see page
3). Check slot for debris.

Advertisement

Table of Contents
loading