Mitel 6800 Series SIP Phone Release 4.2.0 Administrator Guide
EXAMPLE
WATCHDOG SETTINGS
PARAMETER –
watchdog enable
DESCRIPTION
FORMAT
DEFAULT VALUE
RANGE
EXAMPLE
A-302
Enter a debug level value in the "Debug Level" field for a module.
Example 1
To turn two or more debug levels on at the same time, you add the
value associated with each level. For example,
Fatal Errors + Errors + Warnings = 1 + 2 + 4 = 7
log module linemgr: 7
log module user interface: 7
log module sip: 7
In the above example, fatal errors, general errors, and warnings are
logged for the line manager, user interface, and SIP call control
modules.
Example 2
Functions and Info = 16 + 32 = 48
log module dis: 48
log module net: 48
log module snd: 48
In the above example, functions and general information are logged
for the display drivers, network, and sound modules.
Example 3
log module rtpt: 0
log module ind: 65535
In the above example, all debug levels are OFF for the Real Time
Transport module. All debug levels are ON for the indicator module.
You can set the Module/Debug Levels using the configuration files
or the Mitel Web UI.
CONFIGURATION FILES
startup.cfg, <model>.cfg, <mac>.cfg
Enables/disables the use of the WatchDog task for the IP Phones.
Boolean
1 (enabled)
0 (disabled)
1 (enabled)
watchdog enable: 0