General Adjustments - Copying And Printing; To Obtain High-Density Image In General - Toshiba E-studio 210c Imaging Manual

Hide thumbs Also See for E-studio 210c:
Table of Contents

Advertisement

1. General Adjustments – Copying and Printing

1.1 To Obtain High-density Image in General

Before the adjustment
The copy image looks light and blurred.
Explanation
When an original containing a photo or gradations is printed, the copy image sometimes looks light and blurred
in general. Perform automatic calibration (γ adjustment) and calibration, and adjust the transfer bias to obtain
darker and sharper image in general.
Procedures
* Perform the adjustment in accordance with the procedures below.
* Procedures (1), (3) and (4) are used by the service technician only.
* Procedure (2) is used by the service technician, and by the user.
(1) Enter adjustment mode [05], select code [878], and press the [START] button.
• Image quality control will be forcibly performed to correct variations in density.
After executing the image quality control, print and check the image quality.
If further image quality adjustments are still necessary, use the next procedure.
1.1
e-STUDIO210c/310c, e-STUDIO211c/311c
After the adjustment
The copy image looks darker and sharper.