Sign In
Upload
Manuals
Brands
Labconco Manuals
Laboratory Equipment
Logic+ B2
Labconco Logic+ B2 Manuals
Manuals and User Guides for Labconco Logic+ B2. We have
3
Labconco Logic+ B2 manuals available for free PDF download: Technical Manual, User Manual
Labconco Logic+ B2 Technical Manual (201 pages)
Biosafety Cabinets, Procedure Stations
Brand:
Labconco
| Category:
Laboratory Equipment
| Size: 9 MB
Table of Contents
Table of Contents
4
1: Introduction
11
Contacting Labconco
11
About this Manual
12
Theory of Operation
12
Type A2
12
Type B2
13
Type C1 - a Mode
13
Type C1 - B Mode
14
2: Safety Precautions
15
Typographical Conventions
15
General Safety Precautions
17
Safety Precautions for this Product
19
3: Catalog Number Configurator
21
4: Serial Tag
22
Serial Tag Location
22
Serial Tag Information
23
Primary Serial Tag
23
Secondary Serial Tag
23
5: Factory Test Report
24
Test Report Location
24
Test Report Information
25
6: Additional Product Information
26
Data Plate Location
26
Data Plate Information
27
7: Exhaust System Connections
28
Exhaust Connection Best Practices
28
Air-Tight Damper
30
Exhaust System Requirements
31
Type A2 Models
31
Cell Logic+ Type A2 Models
32
Type B2 Models
32
Type C1 Models
33
8: Configuration
34
Current Configuration
34
Change Configuration
36
9: Calibration
40
Certifier Password
40
Adjusting Blower Speed
41
Adjusting the Internal Air Damper
43
Setting the Filter Life Gauge
45
Type A2 (8-Inch through 10-Inch Sash) and Type B2
45
Type A2 (12-Inch Sash) and Type C1
46
Airflow Sensor Calibration
47
Type A2 and Type C1
47
Type B2
48
Zero Point Calibration
50
Vacuum Start Switch Calibration (Type C1 Only)
51
10: Certification
53
Certifier Password
53
Type A2 HEPA Filter Leak Test Preparation
53
Theoretical Upstream Concentration
54
Upstream Concentration Sampling
54
Type A2 Supply HEPA Filter Leak Test
56
Acceptance Criteria
57
Type A2 Exhaust HEPA Filter Leak Test
58
Acceptance Criteria
59
Type B2 Supply HEPA Filter Leak Test Preparation
60
Theoretical Upstream Concentration
60
Upstream Concentration Sampling
60
Type B2 Supply HEPA Filter Leak Test
62
Acceptance Criteria
63
Type B2 Exhaust HEPA Filter Leak Test Preparation
64
Theoretical Upstream Concentration
64
Type B2 Exhaust HEPA Filter Leak Test
65
Acceptance Criteria
65
Type C1 Supply HEPA Filter Leak Test Preparation
66
Theoretical Upstream Concentration
66
Upstream Concentration Sampling
66
Type C1 Supply HEPA Filter Leak Test
68
Acceptance Criteria
69
Type C1 Exhaust HEPA Filter Leak Test Preparation
70
Theoretical Upstream Concentration
70
Type C1 Exhaust HEPA Filter Leak Test
72
Acceptance Criteria
73
Downflow Velocity
74
Acceptance Criteria
75
Inflow Velocity
76
Primary Method
76
Acceptance Criteria
78
Secondary Method
79
Acceptance Criteria
83
Work Area Air Cleanliness Test (Optional)
84
Acceptance Criteria
84
Lighting Test (Optional)
85
Acceptance Criteria
85
Noise Test (Optional)
86
Acceptance Criteria
86
Vibration Test (Optional)
86
UV Light Intensity Test (Optional)
87
Acceptance Criteria
87
Ground Fault Circuit Interrupter (GFCI) Test
88
Acceptance Criteria
88
11: Quickcharts
89
Quickchart - Type A2 3-Ft & 4-Ft
90
Quickchart - Type A2 5-Ft & 6-Ft
91
Type A2 Footnotes
92
Quickchart - Type B2
93
Type B2 Footnotes
94
Quickchart - Type C1
95
Type C1 Footnotes
96
12: Advanced Service Procedures
97
Tools
97
Required
97
Optional
97
Removal of External Dress Panels
98
Dress Panel
98
Side Panels
99
Front Sash
100
Sash Level Adjustment
100
Sash Sensor Adjustment or Replacement
101
HEPA Filter Replacement
104
Type A2 (8, 9, 10-Inch Sash)
104
Type A2 (12-Inch Sash)
107
Type B2
110
Type C1
114
Blower/Motor Replacement
117
Type A2 (8, 9, 10-Inch Sash) & B2
117
Type A2 (12-Inch Sash) & C1 Supply Blower/Motor
121
Type A2 (12-Inch Sash) & C1 Exhaust Blower/Motor
124
Changing the LED Lamps
129
LED Lamp Socket Cap Replacement
131
Changing the Optional UV Lamp
132
UV Lamp Socket Replacement
133
Type B2 Prefilter Replacement
134
Air-Tight Damper Adjustment
135
Preparing the Biosafety Cabinet for Gaseous Sterilization
136
Service Fixture Installation & Service Connection
137
13: Electrical Components
140
Electronics Module
140
Electronic Module Components
141
Resetting a Circuit Breaker
142
Power Supply Board
143
Display Board
144
Speaker
145
Blower Motor
146
Wiring Diagrams
148
100-115V
148
208-240V
149
14: Troubleshooting
150
Blower and Lights Not Working
150
Blower Only will Not Start
151
Lights Only will Not Illuminate
152
UV Light will Not Illuminate
153
Airflow Alert Activating
154
Filter Life Gauge Not at 100% When New
155
Contamination in the Work Area
156
15: Diagnostics
157
Sash Sensors
157
Keypad
158
Airflow Sensor (Optional)
159
Canopy (Optional)
160
16: Bms Data Output Connection
161
Connection Type
161
Data Output Format
162
Data Output Rate
162
Data Output String Definition
163
Data Output Software Requirements
164
17: Ventus Canopy Connection Kit
165
Kit Catalog Numbers
166
Installation Procedure
166
Exhaust Damper Installation Procedure
168
Canopy Switch Wiring Connection
168
Calibrate for Operation
169
18: Airflow Sensor Kit
171
Installation - Type A2 Without Ventus Canopy
171
Installation - Type A2 with Ventus Canopy
173
Connection to Electronics Module
175
Configuration (New Install Only)
176
Calibration
178
19: Uv Lamp Kit
181
Kit Catalog Numbers
181
Installation
181
Configuration
183
20: IV Bar Kit
185
Kit Catalog Numbers
185
Installation
185
21: Prefilter Kit
187
Kit Catalog Numbers (Type A2 and B2 Only)
187
Installation
187
Attach Prefilter(S) to Towel Catch - G4 Paper
188
Attach Prefilter(S) to Towel Catch - Aluminum Washable
189
22: en Alarm/Relay Contact Kit
190
Installation
190
Example 1 - Blower Relay Contact (Single Phase AC)
194
Example 2 - Blower Relay Contact (Three Phase AC)
195
23: Parts List
196
Type A2 Consumables
196
Type B2 Consumables
197
Type C1 Consumables
198
Advanced Service Components
199
Advertisement
Labconco Logic+ B2 User Manual (95 pages)
Biosafety Cabinets
Brand:
Labconco
| Category:
Laboratory Equipment
| Size: 4 MB
Table of Contents
Table of Contents
4
1: Introduction
9
About this Manual
9
Contents Included
9
2: before You Install
10
Location Requirements
10
Clearance Requirements
11
Electrical Requirements
11
Service Line Requirements
11
Exhaust Requirements
12
Air-Tight Damper
14
User-Supplied Microscope Requirements - Scope-Ready
14
TM Package Only
14
User-Supplied Circulator Requirements - Temp-Zone
15
TM Package Only
15
3: Safety Precautions
16
Typographical Conventions
16
General Safety Precautions
18
Safety Precautions for this Product
20
4: Installation
22
Unpacking
22
Electrical Connection
27
Service Line Connection
28
Drain Valve Installation (Optional)
29
Exhaust Connection
30
Microscope Installation (Optional)
31
Circulator Installation (Optional)
33
Figure
34
Certification
35
5: Performance Features
36
Laminar Airflow
36
Directional Airflow
37
Cabinet Air Intake (Front Grille)
37
HEPA Filters
38
ULPA Filters
38
Motor/Blower
39
Airflow Sensor
39
UV Lamp (Optional)
40
Scope-Ready TM Package (Optional)
40
Pure-Vu™ Seal
40
Stand-Still TM Isolation Platform
41
Temp-Zone TM Package (Optional)
41
6: Mylogic Operating System
42
Home Screen
42
Display Sleep Mode
43
Keypad
43
Main Menu
44
Configuration Submenu
45
Audible Tones
45
Selecting a Language
45
Setting the Clock
46
Setting Automatic Operation Options
47
Tm )
47
Navigating the Settings Submenu
48
Selecting the Units of Measure
48
Activating the Security Lock
48
Setting the USB Output Rate
48
UV Parameters
49
The Tools Submenu
49
Timer Operation
50
Interval Timer Operation
50
Stopwatch Timer Operation
50
Airflow Alert
51
Resetting the Airflow Alert System
51
Alarms
52
Power Loss Alarm
52
Sash Height Alarm
52
Blower Failure Alarm
52
Exhaust Airflow Check
53
Running Exhaust Alarm
53
7: Using Your Cell Logic+ Type B2
54
Feature Overview
54
System Reset Switch
55
Keypad
56
Sash Operation
57
Blower Operation
57
Light Operation
57
Outlet Operation
57
Vacu-Pass TM Cord & Cable Pass Thru (Optional)
58
Working in the Cabinet
59
Planning
59
Cabinet Start-Up
59
Wipe down
59
Loading Materials and Equipment
60
Work Techniques
60
Final Purging
60
Unloading Materials and Equipment
60
Wipe down
60
Shutdown
61
8: Maintaining Your Cell Logic+ Type B2
62
Maintenance Safety Precautions
62
Recommended Maintenance Schedule
63
Service Operations
64
Resetting a Circuit Breaker
64
Dished Work Surface Removal
65
Front Grille Removal
65
Front Panel Removal
66
Changing the LED Lamps
67
Changing the Optional UV Lamp
69
Storage
70
9: Accessories
71
Telescoping Base Stands
71
Manual or Electric Hydraulic Lift Base Stands
71
IV Bar
72
Stand-Still TM Isolation Platform
72
Pure-VU TM Seals
72
10: Troubleshooting
73
Blower and Lights Not Working
73
Blower Only will Not Start
74
Lights Only will Not Illuminate
75
UV Light will Not Illuminate
76
Airflow Alert Activating
77
Filter Life Gauge Not at 100% When New
78
Contamination in the Work Area
79
Exhaust Alarm Activates 60 Seconds after Turning the Blower on
80
Appendix A: Parts List
81
Appendix B: Dimensions
83
Appendix C: Specifications
84
Power Data
84
Motor Specifications
84
Environmental Conditions
85
Appendix D: Quick Chart Reference
86
Appendix E: Installation Guide: Pure-Vu Seals and Stand-Still Isolation Platforms
87
Pure-Vu Template
94
Labconco Logic+ B2 User Manual (93 pages)
Biosafety Cabinets
Brand:
Labconco
| Category:
Laboratory Equipment
| Size: 4 MB
Table of Contents
Table of Contents
4
1: Introduction
9
About this Manual
9
Contents Included
9
2: before You Install
10
Location Requirements
10
Clearance Requirements
11
Electrical Requirements
11
Service Line Requirements
11
Exhaust Requirements
12
Air-Tight Damper
13
3: Safety Precautions
15
Typographical Conventions
15
General Safety Precautions
17
Safety Precautions for this Product
19
4: Installation
21
Unpacking
21
Electrical Connection
26
IEC Connector
26
Ethernet Connection
27
Service Line Connection
28
Drain Valve Installation (Optional)
29
Exhaust Connection
30
Certification
31
5: Performance Features
32
Laminar Airflow
32
Directional Airflow
33
Cabinet Air Intake (Front Grille)
33
HEPA Filters
34
ULPA Filters
34
Motor/Blower
35
Airflow Sensor
35
UV Lamp (Optional)
36
6: Logic Type B2 Operating System
37
Home Screen
37
Display Sleep Mode
38
Keypad
38
Navigating the Data Logs Menu
39
Navigating the Settings Menu
41
Configuration Submenu
41
Adjusting Sound
43
Selecting a Language
44
Setting the Clock
44
Selecting the Units of Measure
45
Activating the Security Lock
45
Setting the Data Acquisition Rate
45
Adjusting the Display
45
Utilizing Network Connection
46
Activating Email Alerts
46
Adjusting Maintenance Reminders
48
The Certification Submenu
49
Navigating the Help Menu
49
About
50
Software Update Via USB Thumbdrive
51
Software Update Via the Ethernet
51
Automatic Update Notification
51
Sensors
52
Diagnostics
53
Resources
53
Notifications
54
Timer Operation (Optional)
54
Alerts
55
Airflow Blockage
55
Resetting the Airflow Blockage Alert System
56
Exhaust Airflow Check
56
Alarms
56
Power Loss Alarm
57
Sash Height Alarm
57
Memory Failure
58
Blower Failure Alarm
58
Exhaust Failure Alarm
59
7: Using Your Logic Type B2
60
Feature Overview
60
System Reset Switch
61
Keypad
62
Sash Operation
63
Blower Operation
63
Light Operation
63
Outlet Operation
63
Vacu-Pass TM Cord & Cable Portal (Optional)
64
Working in the Cabinet
65
Planning
65
Cabinet Start-Up
65
Wipe down
66
Loading Materials and Equipment
66
Work Techniques
66
Final Purging
66
Unloading Materials and Equipment
66
Shutdown
67
8: Maintaining Your Logic Type B2
68
Maintenance Safety Precautions
68
Recommended Maintenance Schedule
69
Service Operations
70
Resetting a Circuit Breaker
70
Cleaning Beneath Dished Work Surface
71
Front Grille Removal
72
Front Panel Removal
73
Changing the LED Lamps
73
Towel Catch Removal
75
Changing the Optional UV Lamp
76
Storage
77
9: Accessories
78
IV Bar
78
Sash Prop
78
Telescoping Base Stands (Non-Welded)
79
Telescoping Base Stands (Welded)
79
Electric Hydraulic Lift Base Stands (with Leveling Feet)
79
Electric Hydraulic Lift Base Stands (with Casters)
80
10: Troubleshooting
81
Blower and Lights Not Working
81
Blower Only Will Not Start
82
Lights Only Will Not Illuminate
83
UV Light Will Not Illuminate
84
Airflow Alert Activating
85
Filter Life Gauge Not at 100% When New
86
Contamination in the Work Area
87
Exhaust Alarm Activates 60 Seconds after Turning Blower on
88
Appendix A: Parts List
89
Appendix B: Dimensions
90
Appendix C: Specifications
91
Power Data
91
Motor Specifications
91
Environmental Conditions
92
Appendix D: Quick Chart Reference
93
Advertisement
Advertisement
Related Products
Labconco Precise Basic 5220000
Labconco Precise Basic 5220020
Labconco Precise Basic 5220021
Labconco Precise Basic 5220030
Labconco Precise Basic 5220031
Labconco Capture BT 31700-00
Labconco Capture BT 31700-01
Labconco Capture BT 31700-02
Labconco Capture BT 31700-04
Labconco Capture BT 31700-05
Labconco Categories
Laboratory Equipment
Ventilation Hood
Dryer
Enclosure
Fan
More Labconco Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL