Field Service Ver. 2.0 Feb. 2006
Maintenance
2.

Periodical check

2.1

Maintenance procedure (Periodical check parts)

NOTE
• The alcohol described in the cleaning procedure of Maintenance represents the
isopropyl alcohol.
2.1.1
Cleaning Transport Roller / Roll 1, 2
[2]
[3]
2.1.2
Cleaning Transport Roller / Roll 3
[1]
1. Open the Duplex Unit Door [1].
2. Using a soft cloth dampened with
alcohol, wipe the Transport Roller /
Roll 1 [2], 2 [3] clean of dirt.
[1]
4066F2C503DA
1. Remove the Duplex Unit.
See P.6
2. Using a soft cloth dampened with
alcohol, wipe the Transport Roller /
Roll 3 [1] clean of dirt.
4066F2C504DA