16. Malfunction code
16.5.75
CA051: Standard Controller configuration failure
16.5.76
CA052:Controller hardware error
16.5.77
CA053: Controller start failure
MFP Control Board (PWB-MFP)
Step
Check to see if the following setting has
been correctly made: [Service Mode] →
[System 2] → [Image Controller Setting].
1
If changing the setting, turn OFF the Main
Power SW and turn it ON again after 10
seconds or more.
Check the connectors of the MFP Control
2
Board (PWB-MFP) for proper connection
and correct as necessary.
3
Change PWB-MFP
16.5.78
CC001: Vendor connection failure
Mechanical Control Board (PWB-M)
Step
Check the Vendor connector for proper
1
connection and correct as necessary.
Check the PWB-M connector for proper
2
connection and correct as necessary.
3
Change PWB-M
460
Relevant Electrical Parts
Action
Relevant Electrical Parts
Action
Field Service Ver. 3.0 Aug. 2006
WIRING DIAGRAM
Control Signal
—
—
—
Coin Vendor (Japan)
Coin Vendor Kit (North America, Europe)
WIRING DIAGRAM
Control Signal
—
—
—
Location (Electri-
cal Component)
—
—
—
Location (Electri-
cal Component)
—
—
—