Field Service Ver. 3.0 Aug. 2006
14. Mechanical adjustment
14.1 Mechanical adjustment of the scanner section
14.1.1
Adjustment of the Scanner Motor Belt
This adjustment must be made in the following case:
• The Scanner Motor Assy has been removed.
• The Scanner Drive Cables have been rewound.
1. Remove the Upper Rear Cover and the IR Rear Cover.
See P.82, P.79
[2]
[3]
[1]
4038F2C128DA
[4]
4038F2C129DA
14. Mechanical adjustment
2. Remove the Harness from two Wire
Saddles [1] and the Edge Cover [2].
3. Disconnect the Connector [3], and
remove the Harness from the Wire
Saddle [4].
387