Field Service Ver. 3.0 Aug. 2006
18.3.7
Scanner System: moire
A. Typical Faulty Images
B. Troubleshooting Procedure
Step
Section
Original
1
Basic Screen
2
Quality/Density
Basic Screen Zoom
3
4036fs4033c0
Check Item
Moire distortions recur even after
the orientation of original has been
changed.
Moire distortions recur even after
the original mode has been
changed.
The problem has been eliminated
through the checks of steps up to 2.
18. Image quality problem
Result
Action
NO
Change the original mode
(select one other than that
resulted in moire).
YES
Select "Text Mode" or
"Photo Mode".
NO
Change the zoom ratio.
483