10. Service Mode
C. Cross Direction Adjustment
Functions
• To adjust the zoom ratio in the main scan direction for the Scanner Section
Use
• The CCD Unit has been replaced.
Adjustment
Specification
Adjustment
If the C width on the copy sample is less than one on color chart, increase the setting.
Instructions
If the C width on the copy sample exceeds one on color chart, decrease the setting.
Setting/
1. Call the Service Mode to the screen.
2. Touch these keys in this order: [Machine] → [Scan Area] → [Cross Direction Adjust-
Procedure
ment].
3. Position the Color Chart correctly so that the original reference point is aligned with
the scale.
4. Press the Start key to make a copy.
5. Check the C width on the image of the copy.
6. If the image falls outside the specified range, change the setting using the [+] / [-]
key.
7. Press the Start key to make another copy.
8. Check the image on the copy to see if the specifications are met.
9. Make adjustments until the specifications are met.
306
•Measure C width on the color chart and on
the sample copy, and adjust the gap to be
within the following specification.
•An adjustment must have been completed
correctly of "Paper Feed Direction Adj." of
Printer Area.
C
Specifications
C: ± 1.0 mm
4038F3C516DA
Setting Range
0.990 to 1.010 (in 0.001 increments)
Field Service Ver. 3.0 Aug. 2006