Solution - Konica Minolta bizhub C250 Service Manual

Hide thumbs Also See for bizhub C250:
Table of Contents

Advertisement

8. Trouble code
8.3

Solution

8.3.1
C0001: LCT communication error
Control Board (PWB-C1 LCT)
Step
Turn OFF the Main Power Switch, wait
1
for 10 sec. or more, and turn ON the
Main Power Switch.
2
PWB-C1 LCT replacement
8.3.2
C0209: LCT Elevator Motor Failure
Elevator Motor (M5-LCT)
Elevator Motor Pulse Sensor (PC10-LCT)
Step
Check the motor and sensor connectors
1
for proper connection, and correct as
necessary.
Check the connector of motor for proper
2
drive coupling, and correct as neces-
sary.
3
PC10-LCT I/O, sensor check
4
M5-LCT operation check
5
PWB-H LCT replacement
6
PWB-C1 LCT replacement
32
Relevant electrical parts
Action
Relevant electrical parts
Action
PWB-H LCT PJ2H<B> LCT-6 to 7 PC-403 G to H-5
Field Service Ver. 1.0 Jul. 2005
WIRING DIAGRAM
Control signal
Interface Board (PWB-H LCT)
Control Board (PWB-C1 LCT)
WIRING DIAGRAM
Control signal
PWB-H LCT PJ2H<A> LCT-5
(ON)
Location
(Electrical
components)
Location
(Electrical
components)
PC-403 G to H-4