Field Service Ver. 3.0 Aug. 2006
(4) Print Lists
• It will not be displayed when the following setting shows that Authentication Device or the
1
Vendor is mounted.
[Service Mode] → [Billing Setting] → [Management Function Choice]
(It will be displayed when the Key Counter is mounted.)
Functions
• To set the Paper Feed Tray for output the list for the Meter count or the Unit check.
• It sets the Simplex/Duplex printing of the output for the Sales counter or the Unit
Use
check list. (Only when the Duplex unit is mounted.)
Setting/
<Paper tray>
Procedure
• The default setting is Tray 1.
<Simplex/Duplex>
• The default setting is 1-Sided.
D. Auto Color Level Adjustment
• It will not be displayed when the following setting shows that Vendor 1 is mounted.
1
[Service Mode] → [Billing Setting] → [Management Function Choice]
Functions
• To set the criterion level to discriminate between a colored original and a black-and-
white original in the Auto Color mode
Use
• To change the criterion level for the partly colored image to be taken as a black-and-
white original
Setting/
• Five levels are available to choose from and the default setting is 3.
Procedure
E. Power Save
1
• It will be displayed only when the following setting is set to "Level 1".
[Administrator Setting] → [Security Setting] → [Administrator Security Level]
• It will not be displayed when the following setting shows that the Vendor 1 is mounted.
(1) Low Power Mode Setting
Functions
• To set the time until Low Power starts operating after the last key operation has been
completed.
• Low Power: To turn LED and LCD OFF, and lower the power consumption.
Use
• To change the time until Low Power starts.
Setting/
• Use the 10-Key Pad for setting.
Procedure
• The default setting is 15 min.
(2) Sleep Mode Setting
Functions
• To set the time until Sleep Mode starts operating after the last key operation has
been completed.
• Turn all lines OFF except 5 V line for Control.
• "OFF" will only be displayed when [No Sleep] in Service Mode is set.
Use
• To change the time until the Sleep Mode starts.
Setting/
• Use the 10-Key Pad for setting.
Procedure
• The default setting is 30 min.
Black
Standard
1
2
"3"
4
"15 min." (10 to 240)
"30 min." (15 to 240) / OFF
8. Utility Mode
Full Color
5
187