Connecting Disk Array Unit; Host Connection; Disk Enclosure Connection - NEC S1300 User Manual

Disk array unit
Hide thumbs Also See for S1300:
Table of Contents

Advertisement

Connecting Disk Array Unit

Host Connection

Disk Enclosure Connection

2-10 Setting Up The DAU
This Manual:http://www.manuallib.com/nec/s1300ug-disk-array-unit-user-guide.html
Figure 2-8. Securing the DAU to the System rack
The following sections provide information for connecting the DAU to the Host
server and the optional disk enclosure. Figure 2-9 show a typical DAU
installation and includes cabling for the optional disk enclosure.
1. Connect the disk array unit with the host using the two supplied
FibreChannel cables. Push the connector at either end of the cable into the
FC connector (HOST-FC) of the disk array controller (CONT0) until a click
is heard. The FC cable has the same connectors at both ends. Either
connector may be connected to the controller. See Figure 2-9.
2. Connect the other end of the FibreChannel cable to the connector of
FibreChannel controller installed in the host system. Connect the second
FibreChannel cable between the second disk array controller (CONT1) and
the host system.
1. Connect either end of the HSSDC-HSSDC cable into the DE-FC connector
(CONT0) on the disk array unit until a click is heard. The HSSDC-HSSDC
cable has the same connectors at both ends. Either connector may be
connected to the controller. Connect the other end of the HSSDC-HSSDC
cable into the FC-IN connector on adapter 0 (ADP0) of the disk enclosure
until a click is heard. See Figure 2-9.
2. Similarly, connect the second HSSDC-HSSDC cable into DE-FC connector
(CONT1) on the disk array unit until a click is heard. Connect the other end
of this HSSDC-HSSDC cable into the FC-IN connector on adapter 1
(ADP1) of the disk enclosure until a click is heard.