12
SET MODE
■ Other set mode
CI–V Address
To distinguish equipment, each CI-V transceiver has
its own Icom standard address in hexadecimal code.
The IC-7700's address is 74h.
CI–V Transceive
Transceive operation is possible with the IC-7700
connected to other Icom HF transceivers or receivers.
CI–V LAN�REMOTE Transceive Address
Sets the CI-V address for sending the transceive
data from [LAN] to [REMOTE] or [RS-232C]. The
[REMOTE] or [RS-232C] connectors output the trans-
ceive data with this setting Address.
When your system are configured with any other
transceivers or receivers, and you do not want to
change their frequency or operating mode by operat-
ing the RS-BA1, sets this address different with 00h.
CI–V Output (for ANT)
Enables to output the antenna controller status (fre-
quency and so on) from [REMOTE].
RS–232C Function
Select [RS-232C] connector output data format from
CI-V and Decode.
Decode Baud Rate
Selects data transmission speed (Baud rate) when
"Decode" is selected in "RS-232C Function" above;
settings are 300, 1200, 4800, 9600 and 19200 bps.
(default: 9600)
Keyboard Type
Selects the connected keyboard type from Japa-
nese, English, United Kingdom, French, French (Ca-
nadian), German, Portuguese, Portuguese (Brazil-
ian), Spanish, Spanish (Latin American) and Italian.
(default: English)
(continued)
12-18
74h
When 2 or more IC-7700's are connected to an op-
tional CT-17
-
ci
v level converter
dial to select a different address for each IC-7700;
the range is 01h to DFh.
ON
When "ON" is selected, changing the frequency,
operating mode, etc. on the IC-7700 automatically
changes those of connected transceivers (or receiv-
ers) and vice versa.
00h
Only when you configure the remote control sys-
tem using an optional RS-BA1, you need this set-
ting.
The IC-PW1 can receive the transceive data from
other than 00h, so you can still operate the IC-PW1
by operating RS-BA1. In that case you must reset the
IC-PW1 and set the CI-V settings again. See the IC-
PW1's instruction manual for details.
OFF
• OFF
: Turns OFF the function.
• ON
: Outputs the status.
CI–V
• CI-V
: Outputs data in CI-V format. (default)
• Decode : Outputs decoded contents in ASCII code